OPERATION
 
 
Refer to Figures 4,5 for adjustment access location, connectors and labels
 
Variable Step Attenuator 
BDA gain that indicated in the spec can be reduced by up to 30 dB in 2 dB steps using the 
variable step attenuator. Gain adjustment is made with rotary switches located inside the BDA 
enclosure. Arrows on the shafts of these switches point to the value of attenuation selected. 
BDA gain can be determined by subtracting the attenuation value from the gain reported on 
the BDA Test Data Sheet for that side of the unit.  The attenuators are labeled for Uplink and 
Downlink
 
ALC (Automatic Level Control)  
 
To minimize intermodulation products, each amplifier in the BDA contains an ALC feedback 
loop. The ALC circuit senses the output power and limits it to the factory preset level, as 
indicated in the specification.   
 
ALC function is located in each power amplifier. A red LED indicator located inside the BDA 
enclosure  (see figure 5) illuminates when output power meets or exceeds the ALC preset 
point.  
 
To establish proper operating gain on the Uplink and Downlink paths, begin with the Downlink. 
Observe the red LED  indicator  labeled DL ALC. Units are shipped from the factory  with 
maximum attenuation  (30 dB). Decrease attenuation one step at a time (each step is 2 dB) 
until the  red  LED  (DL ALC)  is lit. Then, using the Downlink step attenuator, increase the 
attenuation until the red LED goes off. Repeat the process for the Uplink. This setup should be 
done under RF signal transmit for either path the level indicator is accurate to +/- 0.4 dB of the 
ALC set point.  
 
Verify the downlink in-building signal strength and the uplink signal strength at donor antenna 
meets requirements. Reduce the gain if needed (increase attenuation).  
 
 
 
Note: Operation of BDA
 
at maximum gain with greater than -30 dBm 
average power incidents on the MOBILE or BASE ports could cause damage to 
the BDA.