Controlled Electronic Management Systems Ltd S610MSCRM Manuel D’Utilisation
S610S Manual - Hardware Installer Manual - Version 1.8
36
Typical wiring for two turnstiles
Above, typical wiring for two turnstiles/speed-gates or one bidirectional unit with two restrictors
fitted.
fitted.
Controlling power to a turnstile
Sample wiring for a uni-directional turnstile barrier with external PSU.
NOTE: S610E and S610S reader dry contact relay outputs support up to 24V.
Unless set otherwise the default relay states on a reader are Fail Safe.
•
When power fails to a reader the Normally Open position becomes in a Closed state.
•
If the reader output is configured to operate in Fail Secure mode, power failure to the reader
will result in Normally Open remaining in the Open position.
will result in Normally Open remaining in the Open position.
•
An installer should always check Relays states using a multi-meter.
Wiring a bidirectional turnstile
S610E/S610S Inputs and Outputs
S610S or S600E master reader Inputs and outputs in Turnstile modes
IP0
Input
Used to record Turnstile position after Readhead0 cardswipe
Shows an S610E or S610S Master and Exit reader
connected to a sample bi-directional turnstile.
Request to Exit buttons can also be connected to J6 inputs
IP2 and IP3 if required
Shows an S610E or S610S Master reader connected to a
sample bi-directional turnstile.
Request to Exit buttons can also be connected to J6 inputs
IP2 and IP3 if required