Powerwave Technologies Inc. KRB1011108 Manuel D’Utilisation

Page de 42
© 2001 – Ericsson Amplifier Technologies Inc.
5
Table 2. Nominal Gain for Installed Configuration
Operational
Modules less
Non-Operational
Modules*
1 module
System
2 module
System
3 module
System
4 module
System
1
54.5 dB
51.5 dB
49.7 dB
48.5 dB
2
-
54.5 dB
52.7 dB
51.5 dB
3
-
-
54.5 dB
53.2 dB
4
-
-
-
54.5 dB
*Non-operational modules refer to modules which have been disabled due to alarms.
Above values valid during normal operation (26-28VDC input).  Reduce above values by
1 dB during exceptional operating conditions (21-26VDC, 28-30VDC input).
Table 4. DC Power Consumption versus Operating Status
Ericsson MCPA Subsytem Assembly
Operating Status
DC
LED
Status
Enable
LED
Status
DC Power (W)
@ 27V
1 module
DC Power (W)
@ 27V
2module
DC Power (W)
@ 27V
3 module
DC Power (W)
@ 27V
4 module
Prime Power Applied
Internal DC Status
OFF
OFF
OFF
15.0 typ
17.3 max.
30.0 typ.
34.5 max.
45.0 typ.
51.8 max.
60.0 typ.
69.0 max
Bias On
(no RF)
ON
ON
615.0 typ.
707.0 max.
1230.0 typ.
1415.0 max
1845.0 typ.
2122.0 max.
2460.0 typ.
2829.0 max.
Forward Power 100 W
ON
ON
1350.0 typ.
1553.0 max.
Forward Power 200 W
ON
ON
2700.0 typ.
3105.0 max.
Forward Power 300 W
ON
ON
4050.0 typ.
4660.0 max.
Forward Power 400 W
ON
ON
5400.0 typ
6210.0 max