Redline Communications Inc. AN80IE Manuel D’Utilisation

Page de 106
 
 
&
 
 
User 
 
AN-80i 
Manual
 
 
70-00072-01-07 
Proprietary Redline Communications © 2010 
Page 51 of 106 
Sept 18, 2008 
 
4.4 
PMP Screens 
This section describes the configuration screens used to setup a PMP deployment. 
4.4.1  Configuration Screen 
Click 
Configure
 
System
 
in the menu to view and adjust configuration settings for general 
system identification, Ethernet, and the wireless interface (partial screen shown below). 
The highlighted wireless settings are specific to PMP deployments. 
 
Figure 25: PMP - Wireless Settings 
System  Mode:  The  system  designated  as  sector  controller  establishes  and  manages 
the bi-directional data link with a remote end AN-80i. Only one system in a wireless link 
must be set for Sector Controller mode. 
PTP Sector Controller: AN-80i begins transmitting automatically, sends poll 
messages to locate remote AN-80i subscribers, and negotiates operating settings for 
the link. 
PTP Subscriber: AN-80i waits passively, monitoring the selected channel(s) until 
polled by the PTP Sector Controller. 
Registration Period: The polling period for detecting new subscribers. Period is based 
on  the  number  of  wireless  frames  transmitted.  Permitted  values  are  1  to  400.  The 
recommended default registration period is 4. 
Max. Distance [km]: Enter the distance to the subscriber located farthest away from the 
sector  controller  (outer  boundary  of  sector).  This  parameter  is  used  to  optimize 
communications with the subscribers.