SMART Technologies SRP05 Manuel D’Utilisation

Page de 122
designed for pollution degree 1 (P1) as per EN61558-1, which is defined as “No pollution or only dry
non-conductive pollution.”
Electrostatic discharge (ESD)
SMART Response components meet the requirements of EN61000-4-2 severity level 4 for direct and
indirect ESD. No malfunction or damage up to 15 kV (both polarities) with a 330 ohm, 150 pF probe
(air discharge). Unmated connectors meet 8 kV for direct (contact) discharge.
Conducted and radiated emissions
SMART Response hardware’s narrowband radiated electric field meets the limits for Class B
performance, as defined in EN55022/CISPR 22.
Computer requirements
Windows operating systems
l
Pentium® 4 or later processor
l
512 MB of RAM (1 GB recommended)
l
Free hard disk space:
Software
Space required
SMART Notebook software
277 MB
___
Gallery Essentials
549 MB
___
Lesson Activity Toolkit
111 MB
SMART Product Drivers
145 MB
SMART Response assessment software
47 MB
SMART Sync Teacher software
37 MB
Common platform
62 MB
Total
1228 MB
l
Windows® XP SP3, Windows Vista® SP2 or Windows 7 operating system
l
Internet Explorer® Internet browser 6.0 or later
l
Adobe® Flash® Player 10 Firefox® plug-in
l
Adobe Flash Player 10 ActiveX® control for SMART Notebook software
C H A P T E R 2
Getting started
9