Advanced Control Technologies Inc. 0685-0X Manuel D’Utilisation

Page de 3
ZIR000 Instructions
P/D 092704
HomePro
by ADVANCED CONTROL TECHNOLOGIES, INC.
0685-01
2
Mounting the Detector
1.  Place the provided ZIR000 mounting bracket into the location you want to mount it. Mark the wall (or
ceiling) where the two screw holes are that will be used.
2.  Complete the following two steps if mounting in drywall, where there is not a stud.
a.   Drill a pilot hole of 11/64”.
b.   Tap the provided wall anchors into the wall (or ceiling).
3.  Screw the mounting bracket to the wall (or ceiling).
4.  Install the four AA batteries into the ZIR000 and snap the ZIR000 onto the mounting bracket.
5.  Adjust the vertical pattern angle per figure 2, if desired.
Fig 2
LENS can be adjusted to suit your needs by simply rotating the angle of the lens 180 o to change from wide
angle version (Default setting) to long range version if required.
WIDE ANGLE
Angle: 105
o
 x 110
o
Distance: 39 feet (12 meters)
Zone Number: 64
Default Setting
LONG RANGE
Angle: 5
o
 x 5
o
Distance: 14m
Zone Number: 8
Default Setting + 180
o
Walk Test (checking the detection field)
3.  Place the LED jumper in the “On” location. See figure 3.
4.  Replace the top enclosure and screw.
5.  Walk slowing across the field of view (Back and Forth)
and observe the LED – it lights whenever you enter or
exit a sensitive beam. Allow 5 seconds after the LED has
lit to continue the test, this is so the unit can stabilize.
6.  After testing, remove the retaining screw and the top of
the enclosure and  and set the LED jumper back to the
off position.
7.  Replace top enclosure and retaining screw.