Advanced Control Technologies Inc. 0738-02 Manuel D’Utilisation

Page de 3
Z-Wave ZRR150 Instructions, Series 300 Rel. 2.1
010510
HomePro
by ADVANCED CONTROL TECHNOLOGIES, INC.
0738-02
2
INCLUDING  ZRR150 TO THE NETWORK
STEP 1..   Prepare the Controller to include a unit to the network, by selecting “Groups” and “Add Unit to Group”
(method of adding a node to the network).  Refer to controller instructions.
STEP 2.    The ZRR150 must be in its permanently installed location.  Tap the button on the face of the
ZRR150 once when your controller indicates “Press Button on Unit”.
STEP 3.    You should see an indication on your Controller that the “Device was Included” in the network.
NOTE:  If you have trouble adding the ZRR150 to a group it may be that the Home ID and Node ID
were not cleared from it after testing.  You must first “Reset Unit” with your controller to remove it
from the network.  If using the ZTH100 select “Setup” and scroll to “Reset Unit”
Although adding it to a group includes it in the network, removing it from a group does not remove it from the
network.  If removed from a group, it functions as a repeater only.  “Reset Unit” removes it from the network.
Receptacle Configuration
The ZRR150 Receptacle controls the ON and OFF of a load connected to the controlled outlet (see diagram on
page one for identification)
. The other outlet remains powered all the time.  A button on the face of the receptacle
is used to add the module to the wireless network and be controlled from the wireless controller.  With the Wireless
Controller, the ZRR150 Receptacle can be turned ON and OFF remotely, and can be included in groups that
operate at the same time (a group can also be a single module), and in scenes that set a lighting mood.
Local ON and OFF
When the button on the face of the ZRR150 is pressed, the power to the controlled outlet will turn on.  When the
button is pressed again, the the controlled outlet will turn off.
Child Protection
The ZRR150 controlled outlet can be set in a child protect mode by the Wireless Controller. When this mode is
active, a user will have to press the button on the face 3 times rapidly to activate the attached load. The module
operates normally when controlled by the Wireless Controller..
Other functions
The button on the face of the ZRR150 Receptacle can be used to carry out inclusion (add to a group), association
(operate simultaneously with other nodes), exclusion (remove from group) or reset (remove from network). This
is described in more detail in the Advanced Wireless Controller instructions on our web site.
The ZRR150 has a blue indicator LED. This LED will turn on when the controlled outlet is on and will turn off when
the controlled outlet is off.  However, its behavior can be configured as a “night light”  (LED ON when the controlled
outlet is off). See Configuration section below on how to do it.
ADVANCED OPERATION
Configuration
The ZRR150 supports the Configuration command.
The ZRR150 has some features that can be configured (If your controller supports it).
The ZRR150 can be configured to operate slightly differently than how it works when you first install it. You can
use a HomePro ZTH100 Wireless Controller to send Configuration commands (refer to the Setup Menu,
Configuration section of the ZTH100 instructions).  Using the Configuration command you can configure the
following:
Nightlight:
Set this parameter to 0 to have the blue indicator LED show state of controlled outlet (indicator ON = outlet ON).
Set this parameter to 1 to have indicator show the opposite state of controlled outlet (indicator ON = outlet OFF)
•  
Configuration Parameter No 3:
•  
Length: 1 Byte
•  
Valid Values: 0 or 1 (Default: 0)