Advanced Control Technologies Inc. 0778-0X Manuel D’Utilisation

Page de 6
Z-Wave ZDP100 Instructions, Series 300, Release 4.1
052909
HomePro
by ADVANCED CONTROL TECHNOLOGIES, INC.
0778-01
2
BASIC OPERATION
Local Control
The button on the ZDP100 allows the user to
Turn ON, OFF or DIM and BRIGHTEN the load attached to the controlled outlet.
Include or exclude the module from the Z-Wave system
When a controller prompts you to “Send Node ID” or to “Press Button on Unit”, quickly tap  the button on the ZDP100
once to satisfy those instructions.  Further operation of button:
 Tapping button toggles the load attached
Pressing and holding the button will dim or brighten the load attached.
Operation Note
When a light bulb reaches the end of it’s life and burns out, it sometimes creates a momentary short circuit.  The
high current that results may cause the dimmer to respond by turning off.   Should this happen, replace the bulb
with a new one.  The dimmer can now be operated to restore power to the light.
Remote Control
The ZDP100 will respond to BASIC and MULTILEVEL commands that are part of the Z-Wave system. Refer to
your controller’s instructions as to whether your controller can transmit those commands.
See the information in the section titled Version for a complete list of commands the ZDP100 will support.
ADVANCED OPERATION
Protection
The ZDP100 supports the Protection Command.
The ZDP100 can be set to any one of 3 Protection modes by a wireless controller. Refer to your controller for
information on how to set the various modes of Protection. Some controllers may only be able to set certain settings
of Protection.
There are 3 modes of Protection:
1.  No Protection
2.  Child Protection
3.  Button on ZDP100 totally disabled
When Protection is set to “No Protection” mode, the ZDP100 works normally.
When Protection is set to “Child Protection” mode, you will have to press the button 3 times rapidly to toggle the
attached load.  Tap the button twice then press and hold it to dim or brighten the attached load. The ZDP100
operates normally if controlled by a wireless controller.
When Protection is set to “Enable Total Protection” mode, the button will not work. You will be able to turn the load
on and off only with a wireless controller, however the button can still be used to access the Z-Wave network for
programming.
All On/All Off
The ZDP100 supports the ALL ON/ ALL OFF commands.
The ZDP100 can be set to respond to ALL ON and ALL OFF commands 4 different ways.
Refer to your controller for information on how to set the ZDP100 to operate in the manner you desire. Some
controllers may be only able to set certain settings of ALL ON/ALL OFF response.
The 4 different ways the ZDP100 can be setup to respond to ALL ON and ALL OFF commands are:
•   
ZDP100 will not respond to ALL ON or the ALL OFF command.
•   
ZDP100 will respond to ALL OFF command but will not respond to ALL ON command.
•   
ZDP100 will respond to ALL ON command but will not respond to ALL OFF command.
•   