Gemalto M2M GmbH PLS8-USR3 Manuel D’Utilisation

Page de 41
Cinterion
®
 PLS8-US R3 Hardware Interface Overview
3.6 Digital Audio Interface
27
PLS8-USR3_HIO_v03.012
2015-10-13
Confidential / Released
Page 26 of 41
3.6
Digital Audio Interface
PLS8-US R3 supports a digital audio interface that can be employed either as pulse code mod-
ulation interface or as inter IC sound interface. Operation of these interface variants is mutually 
exclusive, and can be configured by AT command (see 
). Default setting is pulse code mod-
ulation.
3.7
Analog-to-Digital Converter (ADC)
PLS8-US R3 provides three unbalanced ADC input lines: ADC1_IN, ADC2_IN and ADC3_IN. 
They can be used to measure three independent, externally connected DC voltages in the 
range of 0.3V to 3.075V.  
3.8
GPIO Interface
PLS8-US R3 has 10 GPIOs for external hardware devices. Each GPIO can be configured for 
use as input or output. All settings are AT command controlled.