Zebra Technologies Corporation MM4300-5800 Manuel D’Utilisation

Page de 80
MOTOMESH DUO 2.0 4300 Users Guide 
November 2007 
2-3 
Ports and Connections 
The following list defines the standard ports and connections for the MOTOMESH Duo 4300 device 
running in either the IAP or MWR modes. 
• 
100-240V A/C Power Cable with flying leads  
• 
One non Power over Ethernet (PoE) Ethernet port   
• 
One Power over Ethernet (PoE) capable port supporting: 
o
  Canopy Connect PoE 
o
  Standards based 802.3af PoE  
 
IAPs can be pre-configured to use Canopy Connect PoE or 802.11 Standards 
Based PoE or with POE Disabled.  
• 
Optional External Personality Plug to activate power over Ethernet Motorola Canopy ™ 
PoE or standards based 802.3af PoE.   
• 
Mounting Bracket 
Operator Supply List 
The Network Operator must supply the following equipment: 
• 
Mounting Location 
• 
Power Source (100-240 VAC depending on IAP configuration) 
• 
Ethernet connection between the IAP and MiSC.  
Optional Antennas 
The following antennas are recommended for use with Infrastructure Devices. 
Table 2-1 
Recommended Antennas for Infrastructure Devices 
Motorola Part Number 
Gain 
Usage 
8571327H01 
8 dBi 
2.4GHz Infrastructure Antenna 
8563328B02 
6 dBi 
2.4GHz Infrastructure Low Power Antenna  
8563328B03 
4 dBi 
2.4GHz Infrastructure Low Profile Antenna 
8571328H01 
10 dBi 
5.8GHz Infrastructure antenna 
8563339B01 
6 dBi 
5.8GHz Low Power Infrastructure Antenna 
RAN4044A 
10 dBi 
5.4GHz Infrastructure Antenna