Zebra Technologies Corporation AP716101 Manuel D’Utilisation

Page de 52
26  
AP 7161 Access Point Installation Guide 
 
 
connections and the top holes on the angle adapter bracket section. Do not tighten  the screws until all rotation 
and tilt adjustments are complete. 
 
11.
To adjust the position of the access point,  rotate  the access point  bracket section  (plus or minus 15 degrees) 
and tilt the angle adapter bracket section  (up to 45 degrees). 
 
12.
Tighten  all hex flange  screws to 60 inch pounds (lbf-in). 
 
 
 
 
For mounting  with  band clamps: 
 
1.  
Attach the pole mount bracket section at the desired mounting location using band clamps. 
 
2.  
With  the angle adapter bracket section positioned so that the open connector slots are on the bottom, attach 
the angle adapter bracket section to the pole mount bracket section using two  1/2 inch bolts and nuts. Tighten 
the nuts to 300 inch pounds (lbf-in). 
 
3.  
Position the access point  bracket section  so that  the bottom  of the section  with  the straight  (not bevel cut) 
sides is oriented  toward  the  bottom  side  of the  AP with  the gore vent. Using a torque wrench or a ratchet and a 
10mm socket, or an adjustable  wrench,  attach  (but 
don’t tighten)  the access point bracket section to the AP 
7161 with  the with  four M6 hex flange screws.