SWR engineering GmbH SR082002AT Manuel D’Utilisation

Page de 11
Electrical connection 
 
 
 
 
Page 11 
5. Electrical connection 
5.1 Connection of the separated version 
 
Fig. 9: Electrical connection of the separated version 
pre-amplifier 
terminal no. 
connection 
input sensor: flex no. 1 
input sensor: flex no. 2 
input sensor: flex no. 3 
input sensor: flex no. 4 
input sensor: flex white 
(
–) GND
 
(+) signal 
(
–) GND
 
input (+)24 V DC 
 
 
Evaluation unit 
terminal no. 
connection 
connection of supply voltage 
input supply voltage 230 V AC 
input supply voltage 230 V AC 
protective earth   
ground 
sensor connection 
1 (sensor) 
(-) GND (from terminal 5 pre-amplifier) 
2 (sensor) 
(+) signal (from terminal 6 pre-amplifier) 
3 (sensor) 
(-) GND (from terminal 7 pre-amplifier) 
4 (sensor) 
output (+)24 V DC (to terminal 8 pre-amplifier) 
5 (sensor) 
ground (optional connection for shielded cable) 
Outputs 
(-) GND output 
(+) output 4...20mA 
(+) output 0...10 V 
 
potential-free relay N.C. 
10 
potential-free relay COM 
11 
potential-free relay N.O. 
current output 
voltage 
output