Digi International Inc XB3C1 Manuel D’Utilisation

Page de 146
Operate in API mode
Frame descriptions
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
129
Modem Status - 0x8A
Description
Cellular component status messages are sent from the device in response to specific conditions.
Format
The following table provides the contents of the frame. For details on frame structure, see
Field name
Field value
Data type
Description
Frame type
0x8A
Byte
Status
##
Byte
0 = Hardware reset or power up
1 = Watchdog timer reset
2 = Registered with cellular network
3 = Unregistered with cellular network
0x0E = Remote Manager connected
0x0F = Remote Manager disconnected