Digi International Inc XB3C1 Manuel D’Utilisation

Page de 146
AT commands
Network commands
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
96
If you change the TM value while in Transparent Mode, the current connection is immediately closed.
Upon the next transmission, the TM value applies to the newly created socket.
If you change the TM value while in API Mode, the value only applies to subsequently opened sockets.
Parameter range
0 - 0xFFFF [x 100 ms]
Default
0xBB8 (5 minutes)
TS (IP Server Connection Timeout)
The IP server connection timeout. If no activity for this timeout then the connection is closed. When
set to the connection is closed immediately after data is sent.]
Parameter Range
10 - 0xFFFF; (x 100 ms)
Default
3000
DO (Device Options)
Enables and disables special features on the XBee Smart Modem according to the following table.
Bit 0 - Remote Manager support
If the XBee Smart Modem cannot establish a connection with Remote Manager , it waits 30 seconds
before trying again. On each successive connection failure, the wait time doubles (60 seconds, 120,
240, and so on) up to a maximum of 1 hour. This time resets to 30 seconds once the connection to
Remote Manager succeeds or if the device is reset.
Bits 1 - 7
Reserved
Range
0x00 - 0x07
Value
Description
0x00
Disable Remote Manager support.
0x01
Enable Remote Manager support.
Default
0x01
EQ (Device Cloud FQDN)
Sets or display the fully qualified domain name of the Remote Manager server.