Digi International Inc XBEEPRO2 Manuel D’Utilisation
XBee®/XBee‐PRO® ZB RF Modules
© 2011 Digi International, Inc.
13
Pin Signals
• Signal Direction is specified with respect to the module
• See Design Notes section below for details on pin connections.
• See Design Notes section below for details on pin connections.
Pin Assignments for the XBee/XBee‐PRO Modules
(Low‐asserted signals are distinguished with a horizontal line above signal name.)
Pin #
Name
Direction
Default State
Description
1
VCC
-
-
Power supply
2
DOUT
Output
Output
UART Data Out
3
DIN / CONFIG
Input
Input
UART Data In
4
DIO12
Both
Disabled
Digital I/O 12
5
RESET Both
Open-Collector with
pull-up
Module Reset (reset pulse must be at least 200
ns)
6
RSSI PWM / DIO10
Both
Output
RX Signal Strength Indicator / Digital IO
7
DIO11
Both
Input
Digital I/O 11
8
[reserved]
-
Disabled
Do not connect
9
DTR / SLEEP_RQ/ DIO8
Both
Input
Pin Sleep Control Line or Digital IO 8
10
GND
-
-
Ground
11
DIO4
Both
Disabled
Digital I/O 4
12
CTS / DIO7
Both
Output
Clear-to-Send Flow Control or Digital I/O 7. CTS, if
enabled, is an output.
13
ON / SLEEP
Output
Output
Module Status Indicator or Digital I/O 9
14
VREF
Input
-
Not used for EM250. Used for programmable
secondary processor.
For compatibility with other XBEE modules, we
recommend connecting this pin voltage reference
if Analog sampling is desired.
Otherwise, connect to GND.
15
Associate / DIO5
Both
Output
Associated Indicator, Digital I/O 5
16
RTS / DIO6
Both
Input
Request-to-Send Flow Control, Digital I/O 6. RTS,
if enabled, is an input.
17
AD3 / DIO3
Both
Disabled
Analog Input 3 or Digital I/O 3
18
AD2 / DIO2
Both
Disabled
Analog Input 2 or Digital I/O 2
19
AD1 / DIO1
Both
Disabled
Analog Input 1 or Digital I/O 1
20
AD0 / DIO0 /
Commissioning Button
Both
Disabled
Analog Input 0, Digital IO 0, or Commissioning
Button