Cross Point b.v. CP301MAXRXA Manuel D’Utilisation

Page de 72
Technical Manual AM Systems 
 
 
 
 
 
Cross Point Device Explorer 
v4.4 
Page 66 of 72 
8.8.2 
AM settings 
The AM settings screen allows specific AM settings to be changed. 
 
Figure 52: AM settings 
 
The Burst frequency setting defines how many times per second a transmission burst is 
send. The available options are: 
@50Hz power frequency 
@60Hz power frequency 
37.5Hz, 50Hz (default), 75Hz and 150Hz 
45Hz, 60Hz (default), 90Hz and 180Hz 
 
 
The  burst  frequency  setting  is  a  system  wide  setting,  which  will  be 
applied  for  all  connected  AM  devices.  It  is  not  possible  to  set  different 
burst frequencies for different entrances.