ADC Telecommunications Inc. F0694-011 Manuel D’Utilisation

Page de 234
Alarm Monitoring Connectivity Options
7-64
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev D
7.8.2
Modem Connection
In this configuration, the PC and the Fusion Wideband Main Hub connect to analog 
modems and communicate using a standard dial-up telephone connection.
Figure 7-40
OA&M Modem Connection 
NOTE: Refer to Appendix A.3 on page A-7 for the modem cable wiring informa-
tion.
Modem switch settings are as follows for US Robotics modem:
• PC-side: 1, 2 and 6 Up 
• Fusion Wideband Hub-side: 2 and 6 Up
7.8.2.1
Setting Up Fusion Wideband Modem (USR Modem) Using 
AdminBrowser
Use the following steps to set up a PPP Dial-In on Fusion Wideband:
1.
Start AdminBrowser as explained in the AdminBrowser manual.
2.
Select System Configuration.
3.
Select Setup Modem Connection. The window shown in Figure 7-41 appears.
Straight-through
modem cable
PC running
Software
Standard Browser
Modem
Straight-through modem cable (#4028-10
)
PSTN
Modem
#140272-0
#4028-10