ADC Telecommunications Inc. F0694-011 Manuel D’Utilisation

Page de 234
Troubleshooting CATV
9-10
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev D
9.4
Troubleshooting CATV
The following table summarizes CATV problems, as reported by AdminBrowser if a 
cable is cut or miswired.
NOTE: Recommended minimum and maximum CATV cable lengths vary 
depending upon the type of CATV cable used. Refer to Section 6.1.2, “Cable and Connector Requirements,” on page 6-2.
9.5
Technical Assistance
Call our help hot line for technical assistance:
1-800-530-9960 (U.S. only)
+1-408-952-2400 (International)
Please provide your name, phone number, e-mail address, and the following informa-
tion. An ADC customer service representative will contact you with assistance.
• Company name
• End user name
• Type of system, model number, frequency
• Approximate time in service (warranty), sales order number
• Description of problem
• LED status
• AdminBrowser faults, warnings, and status messages
Table 9-5
Summary of CATV Cable Wiring Problems
Problem Type
Message
Icon
Impact
Loose connec-
tor, shorted con-
ductor or 
improper con-
nection to the 
shield.
None
High phase noise, degraded signal on both 
Downlink and Uplink (high bit error rate)
• No communication with RAU
RAU unable to communicate with Hub, 
degraded performance or RAU off-line
• Portn UL RF path loss is too high
Increased ripple in the uplink path, decreased 
UL gain, or no UL gain
• The DL RF path loss is too high
Increased ripple in the downlink path, RAU 
off-line
• RAUn over current or port short
RAU will not power on.