ADC Telecommunications Inc. F0694-011 Manuel D’Utilisation

Page de 234
A-6
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev D
* Exceeding the distance of copper-clad cable will result in the attached RAU becoming 
non-functional. If the distance of a cable run is at its maximum and is of concern, ADC recom-
mends the use of solid copper cable to ensure successful operation.
A.2
Fiber Optical Cables
• Connects the Main Hub to Expansion Hub(s)
• Transmits (downlink) and receives (uplink) optical signals
• Carries configuration and status information
• Use industry-standard 62.5µm/125µm MMF or Corning SMF-28 fiber, or equiva-
lent.
• SC/APC (angle-polished) connectors are required throughout the fiber network 
(port-to-port), including fiber distribution panels
Table A-1
System Gain (Loss) Relative to CATV Cable Length 
Cable 
Type
Comm-
Scope 
Part 
Number
Plenum 
Rated
Solid 
Copper 
Conductor
Copper 
Clad 
Conductor
Zero-loss 
RF 
Maximum 
Length 
(meters)
Distance 
Where 
RF is 
10dB 
Below 
Input RF 
(meters)
RG-59
2065V
Yes
X
130
180
2022V
Yes
X
100
100*
5572R
No
X
95
95*
5565
No
X
130
180
RG-6
2279V
Yes
X
140
190
2275V
Yes
X
140
150*
5726
No
X
140
140*
5765
No
X
140
190
RG-11
2293K
Yes
X
235
320
2285K
Yes
X
235
300*
5913
No
X
235
300*