INTERACTIVE COMMUNICATIONS INFORMATION TECHNOLOGIES CO. LTD. TC-100E0001 Manuel D’Utilisation

Page de 26
TC-100E ICIT TeleCenter 
User Manual  Ver 1.0   
Copyright ICIT Co. Ltd. 1999  All Rights Reserved  24   
Installation and Troubleshooting Notes for TeleCommunicator 
 
For Win95 Installations  
 
Installed Directories –  
TeleCommunicator can be installed in any directory under a Windows 95 operating 
system. The files TeleCommunicator.exe (main application) and data.mdb (user data) 
must be in the same directory. Sub-directories from this installed directory are 
REQUIRED to be present for proper operation and include a) \image which stores the 
wallpaper graphics, b) \res which stores the wallpaper and label resources and c) 
\mailbox which stores the email and facsimile mail-box directories and saved email and 
fax files. 
 
Version Updates –  
The version of TeleCommunicator installed is displayed under HELP – About 
TeleCommunicator. Updates may be downloaded from the web-site of ICIT America at. 
In most cases, an update will include only a new updated TeleCommunicator.exe main 
application that should be copied over and replace the older version of the same file in the 
installed directory. The users set-up and saved Directory, Email and other settings will be 
available from the new version as the same data.mdb file which stores these settings will 
not be changed. If there is an update that includes other files or updates to data.mdb the 
update will specify and include this information and update procedures to be followed. 
 
Start-Up Error – Com4 or Com5 – 
When TeleCommunicator is started, it will check to verify that interfaces to telephone 
functions are available and operating properly. An error message will be displayed if they 
are not. Reference the VAR and OEM TECHNICAL GUIDE for procedures to determine 
if the error is a software or hardware problem  and follow procedures to correct the 
problem. 
 
Graphics or Wallpaper Display Error – 
 If TeleCommunicator starts and operates, but graphics or logo areas or touch-area 
graphics do not display properly, it is probably that sub-directories required and detailed 
above are not installed properly or graphic files that were set-up as Wallpaper in the 
UTILITY – Function tab have been erased or moved from their original directory. Check 
that the sub-directories are available from the installed directory, check that the  
 
VAR AND OEM TECHNICAL GUIDE 
A VAR and OEM Technical Guide for the TeleCenter is available from ICIT America. It 
includes all of the detailed hardware configurations and software interfaces required to  
program and customize the TeleCenter and operate different operating systems and third 
party applications.