Sutron Corporation RLR-0003-1 Manuel D’Utilisation
Bringing the Benefits of Real-Time Data Collection to the World
23
Default, Max, Min Settings
The table below indicates the default settings and the maximum and minimum ranges it may be set to.
Parameter
Default Setting Minimum
Maximum
Comment
Automeasure Interval
00:15:00
00:00:01
01:00:00
Automeasure Time
00:00:00
00:00:00
23:59:59
Operating Mode
Normal
0 = Normal
1 = Continuous
Avg Time
10.000 sec
0
900
seconds
Right Digits
2
0
7
Stage Units
Feet
0
3
0=feet,1=m, 2=cm,
3=mm
3=mm
Measuring Point
1.00000 feet
-1000000.00499
1000000.00499
Indirectly set when
user sets stage.
user sets stage.
DQAP
Disabled
0=Disabled
1=Enabled
Discharge
Disabled
0=Disabled
1=Enabled
Discharge Equation
Parshall Flume
0=Disabled
1=Enabled
Parshall Flume Width
12 inches
1
600
inches
Coefficient A
1.0000000
-1000000.0049999
1000000.0049999
Coefficient B
1.5000000
-1000000.0049999
1000000.0049999
Gauge Height Shift
0.0000000
-1000000.0049999
1000000.0049999
Weir Coefficient W
1.0000000
-1000000.0049999
1000000.0049999
Station Name
Sutron Radar
1 Char ASCII
24 char ASCII
Numbers included
WDID
Auto Output
Disabled
0=Disabled
1=Enabled
Log Every Subsample
Disabled
0=Disabled
1=Enabled
Log Every Sample
Disabled
0=Disabled
1=Enabled
Log Level Details
Disabled
0=Disabled
1=Enabled
Log Daily Values
Disabled
0=Disabled
1=Enabled
Sample Form Period
1.0 sec
0.1
10000.0
Seconds
PWM slope
0.755105
Contact Customer
Factory Offset
-1.2
Service for further
information on
information on
SigStrCal
3.300
these items.