Sutron Corporation RLR-0003-1 Manuel D’Utilisation

Page de 63
Bringing the Benefits of Real-Time Data Collection to the World 
23 
 
Default, Max, Min Settings 
The table below indicates the default settings and the maximum and minimum ranges it may be set to. 
 
Parameter 
 
Default Setting  Minimum 
Maximum 
Comment 
 
 
 
 
 
Automeasure Interval 
00:15:00 
00:00:01 
01:00:00 
 
Automeasure Time 
00:00:00 
00:00:00 
23:59:59 
 
Operating Mode 
Normal 
0 = Normal 
1 = Continuous 
 
Avg Time 
10.000 sec 
900 
seconds 
Right Digits 
 
Stage Units 
Feet 
0=feet,1=m,  2=cm, 
3=mm 
Measuring Point 
1.00000 feet 
-1000000.00499 
1000000.00499 
Indirectly  set  when 
user sets stage. 
DQAP 
Disabled 
0=Disabled 
1=Enabled 
 
Discharge 
Disabled 
0=Disabled 
1=Enabled 
 
Discharge Equation 
Parshall Flume 
0=Disabled 
1=Enabled 
 
Parshall Flume Width 
12 inches 
600 
inches 
Coefficient A 
1.0000000 
-1000000.0049999 
1000000.0049999 
 
Coefficient B 
1.5000000 
-1000000.0049999 
1000000.0049999 
 
Gauge Height Shift 
0.0000000 
-1000000.0049999 
1000000.0049999 
 
Weir Coefficient W 
1.0000000 
-1000000.0049999 
1000000.0049999 
 
Station Name 
Sutron Radar 
1 Char ASCII 
24 char ASCII 
Numbers included 
WDID 
 
 
 
 
Auto Output 
Disabled 
0=Disabled 
1=Enabled 
 
Log Every Subsample 
Disabled 
0=Disabled 
1=Enabled 
 
Log Every Sample 
Disabled 
0=Disabled 
1=Enabled 
 
Log Level Details 
Disabled 
0=Disabled 
1=Enabled 
 
Log Daily Values 
Disabled 
0=Disabled 
1=Enabled 
 
Sample Form Period 
1.0 sec 
0.1 
10000.0 
Seconds 
 
 
 
 
 
PWM slope 
0.755105 
 
 
Contact Customer 
Factory Offset 
-1.2 
 
 
Service  for  further 
information  on  
SigStrCal 
3.300 
 
 
these items.