Accton Technology SMC2552WG2 Manuel D’Utilisation

Page de 293
Command Line Interface
6-36
6
sntp-server daylight-saving
This command sets the start and end dates for daylight savings time. Use the no 
form to disable daylight savings time.
Syntax
sntp-server daylight-saving 
no sntp-server daylight-saving 
Default Setting 
Disabled
Command Mode 
Global Configuration
Command Usage 
The command sets the system clock back one hour during the specified 
period.
Example 
This sets daylight savings time to be used from July 1st to September 1st.
sntp-server timezone
This command sets the time zone for the access point’s internal clock.
Syntax
sntp-server timezone
 <hours>
hours
 - Number of hours before/after UTC. 
(Range: -12 to +12 hours)
Default Setting 
-5 (BOGOTA, EASTERN, INDIANA)
Command Mode 
Global Configuration
Enterprise AP(config)#sntp-server daylight-saving
Enter Daylight saving from which month<1-12>: 6
and which day<1-31>: 1
Enter Daylight saving end to which month<1-12>: 9
and which day<1-31>: 1
Enterprise AP(config)#