Murata Electronics North America DNT24 Manuel D’Utilisation

Page de 83
www.Murata.com
Technical support +1.678.684.2000
Page 70 of 83
© 2015 by Murata Manufacturing Co. Ltd.
E-mail:
tech_sup@murata.com
DNT24 Integration Guide – 03/04/15
Figure 8.6.1.9
Figure 8.6.1.9 shows the second I/O Setup tab contents, corresponding to Bank 6 ADC input and DAC
output parameters. The ADC and DAC reference voltages, the ADC sampling interval, the high and low
ADC thresholds for event reporting and event reporting triggers on each ADC channel can be set, along
with the initial output values for each DAC channel. The event reporting I/O predelay and alternate GPIO
functions can also be set from this tab.
Figure 8.6.1.10
Figure 8.6.1.10 shows the third I/O Setup tab contents, corresponding to Bank 6 ADC input and DAC out-
put scaling, offset and related parameters. These parameters should not be changed from their defaults
unless precision inputs are available to calibrate the ADC and DAC functions.