Zebra Technologies Corporation RFID-R110XI-03 Manuel D’Utilisation

Page de 184
80
R110Xi/R170Xi User Guide
12/17/04
23063L-003 Rev. 2
RFID Guidelines
^HV
^HV
Host Verification
Description  This command is used to return data from specified fields, along with an 
optional ASCII header, to the host computer. The command can be used with any field that has 
been assigned a number with the 
^RT
 command or the 
^FN
 and 
^RF
 commands.
Format  
^HV#,n,h
The following table identifies the parameters for this format.
Parameters
Details
#
= field number 
specified with another 
command
The value assigned to this parameter should be the same as the one used in 
another command.
Accepted values: 0 to 9999
Default value: 0
n
= number of bytes to be 
returned
Accepted values: 1 to 256
Default value: 64
h
= header
Header (in uppercase ASCII characters) to be returned with the data.
Acceptable values: 0 to 3072 characters
Default value: no header