CRN Wireless LLC CRNSBU Manuel D’Utilisation
2
POWER
•
WIRE AS SHOWN ABOVE ONLY!
DO NOT POWER FROM “AUX” OUTPUT OR
DIRECTLY FROM POWER SUPPLY!
WIRE SIZE CHART
UP to 10 FEET
10 to 50 FEET
50 to 100 FEET
22 Gauge
18 Gauge
14 Gauge
* If a stand-alone power supply is used, the negative (-) terminal must be
connected to the negative (-) terminal of the control panel. Failure to provide this
common negative will prevent the input channels from being triggered.
connected to the negative (-) terminal of the control panel. Failure to provide this
common negative will prevent the input channels from being triggered.
Connect 12VDC from battery as shown.
SmartSense7 (TB1)
-
+ 1
CONTROL PANEL or
POWER SUPPLY*
(-) (+)
12V BATTERY
(4AH Minimum)
-
+
In-line fuse
1
ANTENNA INSTALLATION
•
Gently push Antenna BNC male connector onto Subscriber
Unit BNC female connector. Twist Antenna BNC bayonet to
lock Antenna onto Subscriber Unit.
Unit BNC female connector. Twist Antenna BNC bayonet to
lock Antenna onto Subscriber Unit.
NEVER POWER UNIT
WITHOUT ANTENNA INSTALLED!
DAMAGE WILL RESULT!
INSTALLATION GUIDELINES
•
Mounting locations can ONLY be selected based on RF performance, therefore, it is HIGHLY recommended that the installer follow the
SELECTING A MOUNTING LOCATION section below BEFORE any wires are run to the alarm control panel.
•
Generally, high locations are best. DO NOT mount radio in basement or below grade as unpredictable performance may result.
•
Whenever possible, keep the transmitter in a climate controlled environment. Attics may reach extremely high temperatures in summer months.
Unheated garages may reach extremely cold temperatures in winter months.
•
Avoid locations within 3 feet of large metal objects (air conditioners, metal garage doors, etc.), AC power lines, and fluorescent light fixtures.
•
A fair amount of care may be required to mount the unit so as to achieve an optimal RF path.
•
Unlike smoke detectors, motion detectors, etc., these transmitters draw a substantial amount of current (approximately 1 Amp during transmit) and
require a “clean” 12VDC power source, free from any AC ripple or “noise”. Therefore, follow the instructions for POWER contained herein
require a “clean” 12VDC power source, free from any AC ripple or “noise”. Therefore, follow the instructions for POWER contained herein
EXACTLY! Power the unit from a battery as shown. DO NOT power from the alarm control panel “AUX” power output or directly from a power
supply. DO NOT vary from the Wiring Size Chart. Failure to properly power the unit may cause unpredictable performance over time.
Changes Or Modifications Not Expressly Approved By The Party Responsible For Compliance Could Void The User’s Authority To Operate The Equipment.
CRN Telemetry Devices, Inc.
INSTALLATION
INSTRUCTIONS
Tel: (631) 696-2769
1515 Middle Country Road
CRN
SmartSense7
WIRELESS SUBSCRIBER UNIT
Fax: (631) 698-7943
Centereach, New York 11720 USA
www.crnwireless.com
WARNING:
Failure to read and carefully follow these instructions may jeopardize subscriber security!
SELECTING A MOUNTING LOCATION
•
Install the antenna as shown in Section 1.
•
Temporarily connect power to the transmitter from a fully charged 12V (4AH minimum) battery. DO NOT mount the transmitter at this
time. Temporarily position the unit in the desired mounting location.
time. Temporarily position the unit in the desired mounting location.
•
To transmit a manual test code (code 0), press pushbutton S1 (bottom right corner of board). Each time S1 is pressed the LED (D6,
just above the pushbutton) will light for approximately 1 second while the unit transmits. Confirm each manual test sent is received by
calling the CRN Automated Signal Verification System or the Central Station, and verify each of the signals sent were received.
just above the pushbutton) will light for approximately 1 second while the unit transmits. Confirm each manual test sent is received by
calling the CRN Automated Signal Verification System or the Central Station, and verify each of the signals sent were received.