Risco Ltd. CAV005 Manuel D’Utilisation

Page de 64
WatchIN Installation Manual
 
3
Wall Mount Installation 
Figure 1 
C1
 
Figure 2 
I1
 
Figure 3 
Tamper
Lever
A
T5
T1
B2
W9
B3
W2
B
L1
T3
B1
L2
W3
B4
R1
R2
(not visible)
T2
T6
(not visible)
T4
W5
W6
 
Note
The installation knockouts numbering are marked on 
the back plate. 
1. Open WatchIN front cover  
(unlock C1, Figure 1). 
2. Release internal base (unlock I1, Figure 2). 
3. Select mounting installation as follows: 
Flat Mounting: 
Open knockouts on external base (Figure 3). 
•  B1 - B4: Wall mounting knockouts 
•  T1: Back tamper knockout 
•  W2 / W3: Wires entry knockouts  
45° angle Mounting (Left side 
mounting): 
a.  Open knockouts on external base 
(Figure 3) 
•  L1, L2: Left mounting knockouts  
•  T3: Left tamper knockout 
•  W5 / W6: Wire entry knockouts 
b. Remove tamper spring 
c.  Replace tamper bracket (Item 1) with 
supplied flat tamper bracket (Item 2).  
Item 1 
 
Item 2 
 
d.  Insert Tamper lever B onto T5 and T3 
and secure screw A (Figure 3) 
4.  Insert external wires through external base 
W2, W3 (Flat Mounting) or W5, W6 (Left
 
side
 
mounting) (Figure 3).  
5.  Secure external base to the wall. 
6.  Insert external wires and tamper wires 
through internal base (Figure 4).
 
7.  Secure internal base to external base (lock 
I1, Figure 2). 
8.  Close the front cover (Lock C1, Figure 1) 
after wiring and setting DIP switches. 
9.  Walk test the detector.
 
Figure 4 
 
Note: 
For 45° right side installation use the equivalent units on the external base as follows:
 
Knockouts Description
 
Left
 
Right
 
Mounting Knockouts 
L1, L2 
R1, R2 
Tamper spring knockouts 
T1, T3 
T2, T4 
Tamper  screw anchor  
T5 
T6 
Wiring Knockouts 
W5, W6 
W7, W8