Risco Ltd. RWX73F915 Manuel D’Utilisation

Page de 2
 
Door / Window Sensor 
Model: RWX73F/RWX73M
 
EN
 
Installation instructions 
 
EN
 
1 General Description 
The RWX73 is a 2-way door / window sensor that offers protection 
against opening doors and windows, and against any attempt to 
tamper with the detector using large magnets. 
2 Quick Device Allocation at the Control Panel 
The sensor is automatically programmed to your control panel during 
the on-line installation wizard setup. If you later purchase an extra 
sensor you can enroll it as follows:  
To quickly allocate the sensor at the control panel: 
If the control panel is not already in Learn mode, press the 
 button on the control panel for 5 seconds; the unit beeps once 
as it enters Learn mode (all the LEDs also light up, one after the 
other).  
Remove the plastic wrapping from the batteries before installation 
and make sure the cover is removed so the internal tamper switch is 
accessible.  
Send a signal transmission from the detector by pressing the tamper 
button for at least 2 seconds; the control panel beeps once to accept or 
beeps three times to reject. Once accepted, the system announces the 
device type and its zone (for example, “Sensor, zone 1”).  
When the sensors have been enrolled, short-press the control panel 
button 
 to exit Learn mode; the unit beeps once and the LEDs 
stop flashing. 
Note:
 For future use, it is recommended to write down the sensor 
description, zone number, and installation location of each allocated 
detector. 
3 LED Indication 
• 
Upon successful learning: short flash sequence
 
• 
Normal operation: brief light upon transmission
 
• 
Low battery: short flash sequence during transmission
 
Selecting the Mounting Location 
1. Select a location best suited for communication quality and near 
the intended wired detector. RISCO recommends placing the unit 
at the highest possible position. 
2. Temporarily attach the unit to this point using the two-sided 
adhesive tape. 
3. Generate an alarm signal and verify that the receiver has received 
the signal. If the alarm signal is not detected, reposition the sensor 
and try again.
 
4 Technical Specifications 
Electrical 
Battery Type
 
CR123 3V Lithium Battery
 
Current consumption 
22µA standby
 
Frequency 
915 MHz 
Dead Time (HOLD ON) 
2.5 minutes
 
Supervision Transmission 
0-255 minutes 
Battery Life 
3 years typical 
Contact size 
32 x 35 x 72 mm (1.3 x 1.4 x 2.8 in.) 
Magnet Size:   16 x 11 x 72 mm (0.6 x 
0.44 x 2.8 in.) 
Environmental 
Operating temperature 
0°C to 40°C (32°F to 104°F)
 
Storage temperature
 
20°C to 60°C (-4°F to 140°F) 
* Specifications are subject to change without prior notice 
 
 
 
 
 
 
 
 
 
 
 
 
 
RISCO Group Limited Warranty 
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from 
defects in materials and workmanship under normal use for 24 months from the date of 
production. Because Seller does not install or connect the product and because the product may 
be used in conjunction with products not manufactured by the Seller, Seller can not guarantee 
the performance of the security system which uses this product. Sellers' obligation and liability 
under this warranty is expressly limited to repairing and replacing, at Sellers option, within a 
reasonable time after the date of delivery, any product not meeting the specifications. Seller 
makes no other warranty, expressed or implied, and makes no warranty of merchantability or of 
fitness for any particular purpose. In no case shall seller be liable for any consequential or 
incidental damages for breach of this or any other warranty, expressed or implied, or upon any 
other basis of liability whatsoever. Sellers obligation under this warranty shall not include any 
transportation charges or costs of installation or any liability for direct, indirect, or not be 
compromised or circumvented; that the product will prevent any persona; injury or property loss 
by intruder, robbery, fire or otherwise; or that the product will in all cases provide adequate 
warning or protection. Buyer understands that a properly installed and maintained alarm may 
only reduce the risk of intruder, robbery or fire without warning, but is not insurance or a guaranty 
that such will not occur or that there will be no personal injury or property loss as a result. 
Consequently seller shall have no liability for any personal injury, property damage or loss based 
on a claim that the product fails to give warning. However, if seller is held liable, whether directly 
or indirectly, for any loss or damage arising from under this limited warranty or otherwise, 
regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the 
product, which shall be complete and exclusive remedy against seller. No employee or 
representative of Seller is authorized to change this warranty in any way or grant any other 
warranty.  
WARNING: This product should be tested at least once a week. 
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries 
according to local regulations. 
 
 
 
FCC ID: JE4RWX73F915 
This device complies with part 15 of the FCC Rules. Operation is subject 
to the following two conditions: 
(1) This device may not cause harmful interference, and  
(2) This device must accept any interference received, including interference 
that may cause undesired operation. 
 
Changes or modifications to this equipment which are not expressly approved by 
the party responsible for compliance (RISCO Group's.) could void the user's 
authority to operate the equipment.
 
 
 
FCC Note 
This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates uses and 
can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by 
turning the equipment on and off, the user is encouraged to try to correct the 
interference by one or more of the following measures: 
 
Reorient or relocate the receiving antenna. 
 
Increase the separation between the equipment and the receiver. 
 
Connect the equipment into an outlet on to a different circuit from that to 
which the receiver is connected. 
 
Consult the dealer or an experienced radio/TV technician for help. 
 
 
© RISCO Group 07/16  
 
 
5IN2579