Zebex Industries Inc BT-CRADLE Manuel D’Utilisation
11. Programming
Guide
Scanning a series of programming bar code labels can configure the scanner.
This allows decoding options and interface protocols to be tailored to a specific
application. The configuration is stored in non-volatile memory and will not be lost
by removing power from the scanner.
The scanner must be properly powered before programming. If you are about to
change the cradle host of parameter, the scanner and cradle must be in pairing
status to prevent failure in programming operation.
During the programming mode, the scanner will acknowledge a good and valid
reading with a short beep. It will give long beeps for either an invalid or bad
reading.
11.1 Default
Parameters
The factory default setting table gives the default settings of all the programmable
parameters. The default settings will be restored whenever the "Reset"
programming label is scanned and the laser scanner is in programming mode.
Factory Default Setting
parameters. The default settings will be restored whenever the "Reset"
programming label is scanned and the laser scanner is in programming mode.
Factory Default Setting
Parameter Default
Radio communication
Bluetooth Host
Bluetooth Host
Cradle Host
Pairing mode
Unlocked
Data transmit
Normal
Radio protocol timeout
5 seconds
Power off timeout
20 minutes
Encryption Enable
Cradle Host
RS-232 communication
Baud rate
9600
Parity none
Data Bits
Data Bits
8
Stop Bit
1
RTS/CTS off
Terminator <CR><LF>
Keyboard Wedge Communication
Terminator <CR><LF>
Keyboard Wedge Communication
Terminal Type
PC/AT
Keyboard US
keyboard
Terminator Enter(Alpha
numeric)
USB Communication
Terminator type
Enter
Code mode
Scan code
32