Description
1Fh Page
number
20h
Protocol configuration 4
21h CID
22h RxWait
23h
Modulation conductance 1 (Type B and SR176)
24h
Modulation conductance 2 (Type B and SR176)
25h
Modulation conductance 3 (Type B and SR176)
26h - 7Fh
RFU
80h … EFh
User data
2.2.2 Unique Device ID (00h – 04h)
The unique device ID identifies a reader module. It is factory programmed and cannot be changed.
2.2.3 Station ID (0Ah)
Default = 01h
The station ID is used in binary mode to address a device in party line set up. The station ID can
range from 01h to FEh and can be set freely. The value 00h is reserved for the bus master. All
readers send their response to this device.
range from 01h to FEh and can be set freely. The value 00h is reserved for the bus master. All
readers send their response to this device.