So far many details of the hardware are not covered. The information is 
provided in this section. 
10.1. S
ERIAL 
P
ORT 
C
ONFIGURATION
 
The serial ports in the NetCom Devices follow the specifications of 
RS 232. It is also possible to use the serial port in RS 422 or RS 485 
mode. This is defined by a set of DIP-switches or by software. Here is a 
list of the available modes and the switch settings. 
Warning: a bad configuration may cause serious damage in the 
NetCom or the connected device. 
 
Line Mode, Comment 
S1 S2 S3 S4
Switch 
positions 
Configuration via serial port 
Note 1
 Off Off
 
Data communication 
On On
 
RS232 
Reload Factory values 
Off Off
Off On
 
RS422 
Data communication 
Point-to-multipoint 
Off On On On
 
4 wire 
Full Duplex
 On Off
 
2 wire 
Half Duplex with Echo
 Off On
 
RS485 
by ART 
Note 2
 
2 wire 
Half Duplex without Echo
 
On On
Off Off
 
4 wire 
Full Duplex
 On Off
 
2 wire 
Half Duplex with Echo
 Off On
 
RS485 
by RTS 
2 wire 
Half Duplex without Echo
 
On Off
Off Off
 
Note 3
 Selected 
by 
Software 
Off On Off Off
 
Table 10: Master Switch Configuration of NetCom 123, 423, 823RM and 1623RM 
 