Titan Electronics Inc NETCOM423 Manuel D’Utilisation
10. H
ARDWARE
D
ETAILS
So far many details of the hardware are not covered. The information is
provided in this section.
provided in this section.
10.1. S
ERIAL
P
ORT
C
ONFIGURATION
The serial ports in the NetCom Devices follow the specifications of
RS 232. It is also possible to use the serial port in RS 422 or RS 485
mode. This is defined by a set of DIP-switches or by software. Here is a
list of the available modes and the switch settings.
Warning: a bad configuration may cause serious damage in the
NetCom or the connected device.
RS 232. It is also possible to use the serial port in RS 422 or RS 485
mode. This is defined by a set of DIP-switches or by software. Here is a
list of the available modes and the switch settings.
Warning: a bad configuration may cause serious damage in the
NetCom or the connected device.
Line Mode, Comment
S1 S2 S3 S4
Switch
positions
positions
Configuration via serial port
Note 1
Off Off
Data communication
On On
RS232
Reload Factory values
Off Off
Off On
RS422
Data communication
Point-to-multipoint
Off On On On
4 wire
Full Duplex
On Off
2 wire
Half Duplex with Echo
Off On
RS485
by ART
Note 2
2 wire
Half Duplex without Echo
On On
Off Off
4 wire
Full Duplex
On Off
2 wire
Half Duplex with Echo
Off On
RS485
by RTS
2 wire
Half Duplex without Echo
On Off
Off Off
Note 3
Selected
by
Software
Off On Off Off
Table 10: Master Switch Configuration of NetCom 123, 423, 823RM and 1623RM
Page
115
NetCom 123 WLAN, 423 WLAN,