As usual this behaves different in Windows NT. There is no Device 
Manager. To change these standard parameters, open the “Ports” applet 
in the Control Panel. 
However it is suggested you open the new “NetCom Manager” applet 
instead. Change to the “Ports” view as in Image 110: NetCom Manager 
Ports View. Double-click on the small icon at the left side. In this 
dialog go to the “Local Settings” tab, as seen above. 
6.3. P
ERFORMANCE 
I
SSUES
 
However operation through the network causes some extra time, which 
is approximately 5 Milliseconds. With a port internal to the computer 
this time may be just some 100 Microseconds. This has an impact on 
reaction times. Some data protocols may be sensible. A lot of 
configurations are possible to compensate for this. But these have an 
effect on the sheer data throughput of the virtual serial port. 
 
Image 114: NetCom COM Port Performance Settings 
Consequently the configuration starts on the “Performance” tab. There 
are four already defined sets of parameters. The default configuration is 
for “Best 
Performance”. The driver software and the NetCom 
communicate with big data blocks. As a result a reaction on short 
events on the serial port is somehow delayed. For applications operating 
823RM WLAN, 1623RM WLAN  