Itron Inc. 100THONA Manuel D’Utilisation

Page de 34
Programming the 100T-HON Telemetry Module 
 
 
TDC-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 
28 
 
Proprietary and Confidential
 
 
 
 
To verify proper communications 
Note  Itron recommends the following operations to verify communications between the 100T-HON 
telemetry module and the Mercury Instrument. 
1.  For an EVC instrument: send a channel 1 EMMIMO read immediately to collect an electronic corrected 
read. Compare the collected read to the Mercury Instrument LCD reading. 
2.  For and EVC instrument with channel 2 data not set to None: send a channel 2 EMIMO to collect an 
uncorrected read. Compare the collected read to the Mercury Instrument meter dial. 
3.  Confirm the Invalid Access Code tamper is not set. If the tamper is set, check the wire connections and 
repeat the EMIMO and tamper check.