Itron Inc. 100THONA Manuel D’Utilisation
Programming the 100T-HON Telemetry Module
TDC-1346-000 100T-HON Honeywell Telemetry Module Installation Guide
28
Proprietary and Confidential
To verify proper communications
Note Itron recommends the following operations to verify communications between the 100T-HON
telemetry module and the Mercury Instrument.
1. For an EVC instrument: send a channel 1 EMMIMO read immediately to collect an electronic corrected
read. Compare the collected read to the Mercury Instrument LCD reading.
2. For and EVC instrument with channel 2 data not set to None: send a channel 2 EMIMO to collect an
uncorrected read. Compare the collected read to the Mercury Instrument meter dial.
3. Confirm the Invalid Access Code tamper is not set. If the tamper is set, check the wire connections and
repeat the EMIMO and tamper check.