DEI Headquarters Inc. DEI1510 Manuel D’Utilisation

Page de 24
P.20 
User Guide 
AUX 1 
Note:  This  500 mA  negative  Aux 1  output  can  be  used  for  many  different 
applications 
Priority door: 
This great feature allows the user to unlock solely the driver’s door with a single 
press of the 
 button on the transmitter, and to unlock the other doors, 
if desired, by pressing the 
 button for a second time. 
The  output  will  provide  a  1-second  negative  output  when  the 
 button 
is pressed a second time on the transmitter.   
Horn Confirmation: 
AUX 1 can be programmed to trigger the horn every time the 
 button is 
pressed,  or  when  the 
 button  is  pressed  twice  within  3  seconds.  When 
horn  confirmation  is  activated,  panic  mode  is  enabled.  If  horn  confirmation  is 
disabled, panic mode will not be available. 
Horn Chirp Timing 
The pulse duration can be configured by your installer (from 5 ms to 200 ms). 
Multi-car Operation 
This  option  allows  the  owner  of  two  vehicles,  both  equipped  with  the  same 
remote  starter  model,  to  control  both  systems  with  a  single  remote  control.  To 
control the second vehicle: 
Press 
TRUNK LOCK buttons simultaneously: LOCK 
Press 
TRUNK UNLOCK simultaneously: 
UNLOCK 
Press 
TRUNK START/STOP simultaneously:  START 
Press 
TRUNK START/STOP simultaneously:  STOP 
Or 
Press AUX
 2X QUICK  AUX  LOCK
LOCK 
Press AUX
 2X QUICK  AUX  UNLOCK
UNLOCK 
Press AUX
 2X QUICK  AUX  START/STOP:  START 
Press AUX
 2X QUICK  AUX  START/STOP:  STOP 
Press AUX
 2X QUICK  AUX  TRUNK: 
TRUNK