Digital Security Controls Ltd. 18PG9309 Manuel D’Utilisation

Page de 8
PG9309_PG8309_PG4309
PowerG Wireless Magnetic Contact
Device with Hardwired Inputs.
Introduction
The device is a supervised, 2-way wireless PowerG
magnetic contact device with the following features:
l
Built-in reed switch
l
Auto-enrollment process when pulling the tab
l
Two separate auxiliary hard-wired inputs support
normally closed (NC), normally open (NO), end of
line (EOL), double end of line (DEOL), and triple
end of line (TEOL). Both external and internal
inputs can be used at the same time. These hard-
wired inputs can be programmed for use with other
hard-wired sensors. Use only UL/ULC burglary lis-
ted sensors.
l
Smart temperature-sensing capabilities
Note:
l
Second auxiliary input, DEOL, TEOL and tem-
perature sensing support are based on panel sup-
porting version.
l
The temperature sensing feature is supplementary
only and was not evaluated by UL/ULC.
The reed switch and auxiliary inputs behave as separate
transmitters, although they trigger the same RF trans-
mitter. Removing the cover activates the tamper switch.
If configured, LED lights only when reporting alarm or
tamper events. Built-in link quality indicators reduce
installation time by eliminating the need for the installer
to physically approach the control panel. Smart tem-
perature-sensing capabilities issue an alert when the
ambient temperature reaches a predetermined
threshold.
Legend
Figure 1: Legend
Callout Description
A
Flexible Retainer
B
Breakaway base segment for back tamper
C
PCB edge supports
D
Mounting holes
E
Wiring inlet
F
Pull tab
G
LED
H
Three terminal blocks for sensor
I
Enroll button
J
Tamper switch
K
N.O. switch
L
N.C. switch
M
EOL: N.O. switch ; 5.6 kΩ resistor
N
EOL: N.C. switch ; 5.6 kΩ resistor
O
DEOL: N.C. switch only ; 5.6 kΩ resistor
P
TEOL: N.C. switch only ;22 kΩ resistor
Table 1: Legend
Mounting the device
It is highly recommended to attach the transmitter to the
top of the door/window on the fixed frame and the mag-
net to the door or window. Ensure the magnet is located
no more than 6 mm (0.25 in.) from the transmitter’s
marked side.
Note: Once the cover is removed, a tamper message
is transmitted to the receiver. Subsequent removal of
the battery prevents transmission of tamper restore,
leaving the receiver in permanent alert. To avoid this,
press the tamper switch while removing the battery.
Attention!The unit has an optional back tamper switch
under the PCB. As long as the PCB is seated firmly
within the base, the switch lever presses against a spe-
cial break-away base segment that is loosely connected
to the base. Be sure to fasten the break-away segment
to the wall. If the detector unit is forcibly removed from
the wall, this segment breaks away from the base, caus-
ing the tamper switch to open.
Note:
l
For UL Commercial Burglary installations, the use
of the back tamper is mandatory.
Mounting with screws
1.
With the cover removed, flex the retainer and
remove the PCB.
2.
Mark and drill two holes in the mounting surface.
3.
Align the device with the magnet according to the
location marks and fasten the device and magnet to
the mounting surface.
4.
Fasten the base with 2 countersunk screws.
5.
Mount the magnet base with the 2 supplied screws.
6.
Attach the magnet to the magnet base.
Note:For UL Commercial Burglary installations, the
use of the back tamper is mandatory.
Mounting with adhesive tape
1.
Peel away the release liners from the two strips of
double-sided adhesive tape and attach to the device
and magnet.
2.
Align the device with the magnet according to the
location marks and fasten the device and magnet to
the mounting surface.
Note: Adhesive mounting tape cannot be used for UL,
cUL, or EN certified installations.
Enrolling the device
1.
Enter the installer menu and select 02: ZONES /
DEVICES 
.
2.
Select ADD NEW DEVICES.
3.
Remove the pull tab to start the auto-enrollment
process.
Note:If the panel does not support ID: 110-XXXX, it
enrolls as W / D Contact with the ID: 101-XXXX.
Alternatively, press the enrollment button, restore the
tamper, or enter the number of the device printed on the
label (ID: 110-XXXX).
Inserting or replacing the battery
To insert the battery, complete the following steps: 
1.
Insert a flat-edged screwdriver into the slot and
push upward to remove cover.
2.
Remove the screw and separate the cover from
the base.
3.
Observe polarity and remove the pull tab.
4.
Connect the sensor wire to the terminal block.
To replace the battery, complete the following steps:
1.
Remove the cover
2.
Wedge a flat head screwdriver under the battery
3.
Twist the screwdriver using the base as a lever to
remove the battery.
Note:
l
When manually programming wireless devices, if
a device has been powered up for more than 48
hours it cannot be enrolled into the system until the
device has been tampered and restored. When pro-
gramming the panel using the Quick Enroll pro-
cedure, follow the steps detailed in Enroll the
Device into the System.
l
After restoring a low battery, the system may take
up to 5 minutes to clear the trouble.
Caution: Battery may explode if mistreated. Do not
recharge, disassemble, or dispose of the battery in a
fire. Replace the battery with type GP, Part No. CR-
123A only. Use of another battery may present a risk of
fire or explosion. See the owner's manual for safety pre-
cautions.
Low battery detection
The device includes low-battery condition detection.
When this condition is detected, a trouble message
transmits to the compatible receiver/control panel. This
provides visual identification of the unit that requires a
battery change. For UL commercial burglary install-
ations, replace the battery yearly.
Note: After restoring a low battery, the system may
take up to five minutes to clear the trouble.
Temperature display
Refer to the PowerSeries Neo, iotega, or PowerSeries
Pro Host Installation Manual for the temperature display
procedure.
Note: This is based on the supporting panel version.
Placement testing / local diagnostic
test
Before permanently mounting any wireless device, tem-
porarily mount the device and perform a placement test
by completing the following steps:
1.
Separate the base of the device from the cover.
2.
Press the tamper switch once and release it.
3.
Put the cover on the device to return the tamper
switch to its normal (undisturbed) position. Then
secure the front cover to the base with the case
closure screw.
4.
Open the door or window and verify the red LED
blinks, indicating detection.
5.
After two seconds, the LED blinks three times.
Table 2 indicates received signal strength:
LED response
Reception
Three green LED blinks
Strong
Three orange LED blinks
Good
Three red LED blinks
Poor
No blinks
No communication
Table 2: Signal strength
Important!Only GOOD or STRONG signal strengths
are acceptable. If you receive a POOR signal from the
device, re-locate and re-test the device until a GOOD or
STRONG signal is received.
Note:
l
For UL/ULC installations, only STRONG signal
levels are acceptable. After installation, verify the
product functionality in conjunction with the com-
patible receivers of the PowerMaster Control
Panel.
l
For detailed placement instructions, refer to the
control panel Reference Guide.
Wiring the auxiliary input
Note: Auxiliary input is for supplementary use only and
was not evaluated by UL.
1.
Connect the auxiliary sensor contacts across the
auxiliary input terminals.
2.
If the auxiliary input is defined as NC type, series
connected NC sensor contacts must be used
exclusively. An EOL resistor will not be required.
3.
If the auxiliary input is defined as a NO type, par-
allel connected NO sensor contacts must be used
exclusively. An EOL resistor will not be required.
4.
For EOL supervision, NC sensor contacts can be
used. A 5.6 kΩ EOL resistor must be wired at the
far end of the zone loop.
Figure 2: Alarm circuit options with EOL resistors
Note:
l
For UL installations, the device connected to the ini-
tiating circuit must be located in the same room as
the transmitter.
l
For UL/ULC installations, connect only UL/ULC lis-
ted devices to the auxiliary wiring input.
l
An alarm message is transmitted once the loop is
opened or short circuited.
Configuration
Table 3 shows the available programmable options:
Alarm LED
Default - [Y]
Enables the devices LED to activate when
an alarm event occurs.
Note:
Disable LED to achieve higher bat-
tery life time for commercial use.
Reed Switch
-Default [Y]
Enables or disables the reed switch.
External
Inputs -
Default [Y]
Enables or disables the external input.
Supervision
- Default [Y]
Enables supervision of the device.
Temperature
Sensor
Default
Enables or disables the temperature
sensor.
Note:
 Based on panel supporting version.
Table 3: Programmable options
Selections
Zone EOL/DEOL/TEOL- Default [01]
Configures auxiliary inputs as one fo the following
options:
[00] Disabled
[01]
EOL/DEOL/TEOL
[02] Normally
Open
[03] Normally
Closed
Note:
DEOL and TEOL are based on panel supporting
version.
Table 4: Selections
Range coverage directions
Figure 3: Range coverage directions
Non-metallic surface
Supports
Metallic surface
Open
Close
Direction
Open
Close
20 mm
16 mm
X
14 mm 07 mm
14 mm
11 mm
Y
10 mm 07 mm
27 mm
21 mm
Z
20 mm 17 mm
Note:
Values stated above may vary by up to 10%. For UL
installations, the gaps cannot be greater than the above
measurements. For steel installations, the gaps cannot
be less that 3.175 mm.
Table 5: Range coverage directions
Specifications
Frequency Band: NA amd LATAM: 915 MHz; Europe
and rest of world: 433MHz, 868 MHz
FCC/IC/UL/ULC listed PG9309 (915 MHz);
CE/EN listed PG4309 (433 MHz), PG8309 (868 MHz)
Communication Protocol: PowerG
Alarm Input: One internal, two external
Supervision: Signaling at four minute intervals
Tamper Alert: Reported when a tamper event occurs
Battery type: 3 V Lithium CR-123A type battery GP
Battery Life Expectancy: 8 years with typical use / 5
years with typical commercial use (LED disabled)
Battery Supervision: Automatic transmission of bat-
tery condition data as part of periodic status report and
immediately upon low battery condition detection
Temperature range: -10 ºC to +55 ºC (14 °F to 131
°F). UL/ULC only verified the range 0 ºC to 49 ºC (32 °
F to 120 °F)
Relative Humidity: Up to a maximum 93 % RH, non-
condensing
©2018 Tyco Security Products www.dsc.com
Tech. Support: 1-800-387-3630