Microwave Radio Communications LLC PTX127T1CG Manuel D’Utilisation

Page de 92
 Notices 
Notices-ii
PTX-PRO User and Technical Manual
WARNING - RF Power Hazard
High levels of RF power are present in the unit.  Exposure to RF 
or microwave power can cause burns and may be harmful to 
health.
Remove power from the unit before disconnecting any RF cables 
and before inspecting damaged cables and/or antennas.
Avoid standing in front of high gain antennas (such as a dish 
antenna) and never look into the open end of a waveguide or 
cable where RF power may be present.
RF Exposure - Safe Working Distances
MRC provides this warning for safety purposes with the intent to 
inform the user of the potential hazard of RF exposure.  The 
following guidelines for safe operation were derived from OET 
bulletin 65, August 1997, as recommended by the Federal 
Communications Commission (FCC).
The PTX-PRO 13 GHz Transmitter is a mobile transmitter 
system designed to provide services to broadcast ENG users 
under CFR 74 subpart F and 74.601 TV pickup stations.  This 
unit, operated without an antenna, will not create RF energy 
exceeding 1.0 mW/cm
2
, the FCC limit for exposure.  Once 
connected to an antenna, the potential for harmful exposure will 
be greatly enhanced.
In this situation, a certain distance from the radiator is to be 
maintained.  Calculations need to be performed to understand 
what that safe margin for exposure is.  This is known as the 
Maximum Permissible Exposure (MPE) limit.
Note
Hazardous RF radiation limits and recommended 
distances may vary by country.  Ensure that all 
applicable state and federal regulations are 
observed when using this transmitter.
Calculations provided are for common antennas often utilized in 
the ENG environment.  The following formula used is that 
suggested by OET 65.
Calculating MPE
EIRP = P * (10 ^ (G / 10))  =  (antilog of G/10) * P
P = RF power delivered to the antenna in mW
G = Power gain of the antenna in the direction of interest relative 
to an isotropic radiator
R = distance to the center of radiation of the antenna in 
centimeters
S = MPE in mW/cm² (milliwatts per square centimeters)
Conversions
dBi to numeric gain = Antilog (dBi/10)
Feet to centimeters = Feet * 30.48
Centimeters to Feet = cm * .0328
π = 12.57
User Input
RF power delivered to the antenna = Watts
Antenna gain (referenced to isotropic antenna) = dBi
Distance from the center of radiation = Feet
Calculation steps: