TransCore 05716 Manuel D’Utilisation

Page de 210
Encompass 4 Reader System Guide
7-22
560 Request Sensor Status Change
Command #560 displays the sensor status change reporting. Not applicable to the 
MPRR 
Reader response:
SSTC E<0 to 1>M<0 to 3>
where
E0
Input status change reports disabled (factory default)
E1
Input status change reports enabled
M0
Reporting disabled (factory default)
M1
Changes on input0 reported
M2
Changes on input1 reported
M3
Changes on either input reported
For example, if factory default settings are assigned, the reader message is
SSTC E0 M0
which means that input status change reports are disabled on both input0 and input1.
570 Display Operating Mode Status
Command #570 displays the currently selected tag read mode.
Reader response:
ATA:<E, D> eGo:<I, F, D> SeGo:<I, F, D> IAG:<E, D> Sort:<E, D>
where
I
ID (64 bits)
E
Enabled
F
Full transaction (eATA)
D
Disabled
577 Report Buffered Handshakes
Command #577 reports the buffered handshakes. When in MPRR mode and/or if 
antenna multiplexing is enabled, the response is
Reader response:
HDSH C0 <ww> C1 <xx> C2 <yy> C3 <zz> 
where
ww is count from part 0, xx is count from part 1, yy is count from part 2, and zz is 
count from part 3.