Commands
7-29
SSTC E<0 to 1>M<0 to 3>
where
E0
Input status change reports disabled (factory default)
E1
Input status change reports enabled
M0
Reporting disabled (factory default)
M1
Changes on input0 reported
M2
Changes on input1 reported
M3
Changes on either input reported
For example, if factory default settings are assigned, the reader message is
SSTC E0 M0
which means that input status change reports are disabled on both input0 and input1.
570 Display Tag Protocols
Command #570 displays the currently selected tag protocol.
Reader response:
ATA:<E, D> eGo:<I, F, D> SeGo:<I, F, D> IAG:<E, D> Sort:<E, D> TMM0
where
I
ID (64 bits)
E
Enabled
F
Full transaction (eATA)
D
Disabled
TMM0
Fixed
577 Report Buffered Handshakes
Command #577 reports the buffered handshakes.
Reader message:
XX
where
XX is number of handshakes
#582 Display Synchronization Values