Intellitag® 500 SmartPass® Reader System Modifications
F-8
Enable Diagnostic RF Continuous Wave Command Added
Modification
For diagnostic and testing purposes, a new additional command lets the user test the 
system while continuous wave (CW) RF is being transmitted.  This command lets the 
reader transmit a CW RF signal at the output frequency and attenuation level as 
specified in the associated commands.  Output CW RF is sustained until one of the 
following commands are received by the reader:
6400
Turn RF off
6401
Turn RF on
641
Select RF by input control
There is no data associated with the 
Enable diagnostic RF continuous 
wave
 command.
Commands
This modification introduces the following command:
6402
Enable diagnostic RF continuous wave (new command)