8.2.1.  NTP Settings 
TSC06-C does not have RTC (real-time clock). That means if the power is off, 
the system time will be reset or stopped. 
So at the boot time, TSC06-C will synchronize the system time with the NTP 
server.   
The default NTP settings: 
NTP function enable: Yes 
NTP Server: clock.via.net 
Time Zone: 0 
If TSC06-C failed to connect to the NTP server, it will try again after 1 hour. 
If time synchronization is OK, after 4 hours it will synchronize again. 
After boot up, if TSC06-C detects the system time is not correctly synchronized, 
the power LED will flash once every 5 seconds. 
The user can set the NTP settings from the browser. 
 
Figure 13: System Settings