For the Arm Away mode Entry/Exit Delay, the following rules apply:
When armed, the system audibly beeps once per second announcing that the system is in the Exit
Delay period. During the last 10 seconds of the Exit Delay state, the system audibly fast beeps (two
beeps per second).
When an entry/exit zone is opened, the Entry Delay period sounds an audible beep each second.
The system beeps twice per second in the last 10 seconds of the Entry Delay period. The keypad
code must be entered during this period to avoid sounding an alarm.
A numerical countdown timer on the TouchScreen indicates how much time remains in the Exit
Delay.
If an entry/exit zone is faulted, restored and then faulted again prior to the end of the exit delay
then the Exit Delay is restarted. This only occurs once.
If no Entry/Exit Zone opens and closes during the Exit Delay, the Arming Mode reverts to Armed
Stay.
After Exit Delay, the Security Status header is relabeled Armed Away and sounds 2 short beeps.
If an Entry/Exit zone is opened the Entry Delay period starts with an audible beep each second.
The system beeps twice per second in the last 10 seconds of the Entry Delay period. The keypad
code must be entered during this period to avoid sounding an alarm. During the Entry Delay
period, the motion detectors will not log events.
Arm Stay Mode
The Arm Stay mode is used to arm the system when there are still people in the premises. The following
rules apply:
Alarm trips immediately if a monitored Perimeter zone (non-entry/exit door or window) is opened.
Interior motion detectors not armed.
Entry/Exit zones start an Entry Delay.
Exit Delay starts when the system is armed.
Exit Delay does not beep and is twice the length of Alarm Away mode.
For the Arm Stay mode, the Entry/Exit Delay, the following rules apply:
When an entry/exit zone is opened the Entry Delay period sounds an audible beep each second.
The system beeps twice per second in the last 10 seconds of the Entry Delay period. The keypad
code must be entered during this period to avoid sounding an alarm.
When the system is armed, the Exit Delay period starts, BUT there is no audible beep during the
Exit Delay period (as there is in Arm Away). The Exit Delay period is the time between the system
being armed and the alarms actually being activated. This gives the user time to leave through an
entry/exit security zone.