Technicolor Connected Home USA LLC TCA203 Manuel D’Utilisation

Page de 84
92
The TouchScreen displays the following confirmation:
A USB drive has been inserted, and a firmware upgrade image has been found on it.
Do you wish to upgrade firmware using this image?
4. Tap Upgrade.
The Firmware Update process starts. The TouchScreen reboots after it is complete.
After reboot, the system displays the confirmation dialog again.
5. Tap Cancel, and remove the USB drive.
Enabling Fire Alarm Verification
Fire Alarm Verification causes the system to contact central monitoring when one of the following is true:
Multiple smoke detectors fault
A single smoke detector faults for 60 seconds
By default Fire Alarm Verification is disabled. The system immediately sends an alarm to the central
monitoring station when the smoke alarm trips. However, smoke alarms are notorious for tripping in
non-emergencies (such as, when food burns on the stove or someone forgets to open the flu before
using the fireplace). With the customer’s agreement, this can be avoided using Fire Alarm Verification.
To enable or disable Fire Alarm Verification:
1. From the Installer Settings menu, tap Sensors & Zones ® Fire Alarm Settings.
The Fire Alarm Settings screen is displayed.
Home System Installation Guide