Rosslare Enterprises Ltd HLX24TG Manuel D’Utilisation
Technical Specifications
HLX-24 User Manual
9
2.
Technical Specifications
Electrical Characteristics
External Power Supply
220 VAC/50 Hz, 110 VAC/60 Hz
Operating Voltage Range
15 VDC, 800 mA
Input Current
Standby: 150 mA
Max: 300 mA
Max: 300 mA
Backup Batteries
4 AA (1800 mAh rechargeable batteries are
included)
Display
Two Line, 16 characters, white backlit LCD
PGM Open Collector Output
100 mA, PTC protected
Local Siren
87 dBA @ 1 m (3.28 ft)
Communication (RF) Characteristics
Frequencies
433.92 MHz (G version)
868.35 MHz (H version)
868.35 MHz (H version)
RF Jamming Detection
UL/EN selectable
Anti-collision
Proprietary RF protocol
Programmable No-activity Timer
1–30 minutes, per zone
Reporting
Three private telephone numbers.
Telephone and Modem
Built in dialer & 2400 Baud modem
Environmental Characteristics
Operating Temp. Range
0ºC to 60ºC (32ºF to 140ºF) without battery
0ºC to 45ºC (32ºF to 113ºF) with battery
0ºC to 45ºC (32ºF to 113ºF) with battery
Storage Temp. Range
-25ºC to 70ºC (-13ºF to 158ºF)
Operating Humidity
0 to 85% at 30ºC non-condensing
Dimensions
Height x Width x Depth
174 x 152 x 48 mm
(8.5 x 5.7 x 1.9 in.)
Weight
330 g (11.6 oz)