Rosslare Enterprises Ltd HLX24TG Manuel D’Utilisation

Page de 34
Technical Specifications 
HLX-24 User Manual 
2.
  Technical Specifications 
Electrical Characteristics 
External Power Supply 
220 VAC/50 Hz, 110 VAC/60 Hz  
Operating Voltage Range 
15 VDC, 800 mA  
Input Current 
Standby: 150 mA 
Max: 300 mA 
Backup Batteries  
4 AA (1800 mAh rechargeable batteries are 
included) 
Display 
Two Line, 16 characters, white backlit LCD 
PGM Open Collector Output 
100 mA, PTC protected 
Local Siren  
87 dBA @ 1 m (3.28 ft)
 
 
Communication (RF) Characteristics 
Frequencies 
433.92 MHz (G version) 
868.35 MHz (H version) 
RF Jamming Detection 
UL/EN selectable 
Anti-collision  
Proprietary RF protocol 
Programmable No-activity Timer 
1–30 minutes, per zone 
Reporting 
Three private telephone numbers. 
Telephone and Modem 
Built in dialer & 2400 Baud modem 
 
Environmental Characteristics 
Operating Temp. Range 
0ºC to 60ºC (32ºF to 140ºF) without battery 
0ºC to 45ºC (32ºF to 113ºF) with battery 
Storage Temp. Range 
-25ºC to 70ºC (-13ºF to 158ºF) 
Operating Humidity 
0 to 85% at 30ºC non-condensing 
 
Dimensions 
Height x Width x Depth 
174 x 152 x 48 mm 
(8.5 x 5.7 x 1.9 in.) 
Weight 
330 g (11.6 oz)