Rosslare Enterprises Ltd AYC-E60 Manuel D’Utilisation

Page de 73
Technical Specifications 
AYC-E/Q60 Family Instruction Manual 
11 
2.
 
Technical Specifications 
Specifications 
AYC-E/Q60 
Electrical Characteristics 
Power Supply Type 
Linear type – recommended 
Operating Voltage Range 
5–16 VDC (when used as a controller, 
provided by the secured series intelligent 
power supply) 
Input current standby (12 
VDC) 
110 mA 
Input Current Max (16 VDC)  130 mA 
LED Control Input 
Dry contact N.O. 
Tamper Output 
Open collector, active low, 32 mA max sink 
current  
Cable Distance to Host 
Controller 
Up to 500 ft (150 meters) using an 18AWG 
cable 
Max Proximity Card Read 
Range* 
Rosslare PROX: E – 40 mm, Q – 45 mm 
HID Prox: E – 40 mm, Q – 45 mm 
Proximity Card Modulation  Rosslare PROX/HID Prox at 125 KHz 
Proximity Card 
Compatibility 
Rosslare PROX/HID Prox cards 
Card Transmit Format 
(Reader) 
Rosslare PROX cards: Wiegand 26-bit, or 
Clock & Data 
HID cards: According to card type 
Keypad Transmit Format 
(Reader) 
Programmable PIN code formats 
LED Indicators 
Two tri-colored LEDs 
Communication 
Data1/C1, Data0/C2–open collector, 5 V 
termination 
*  Measured using a Rosslare proximity card (AT-R14) or equivalent. 
Range also depends on electrical environment and proximity to 
metal.