Controller Functionality 
AYC-E/Q60 Family Instruction Manual 
41 
6.5
 
Door Alarms 
Door alarms can be generated by connecting the Auxiliary Input to a 
Door Position Switch. Either Door-Forced or Door-Ajar conditions are 
supported, as well as a configurable delay timer for each alarm type. 
Only one door-alarm is enabled at any one time. Door alarms may 
activate auxiliary output and siren depending on the auxiliary settings. 
6.6
 
Internal Case and Back Tamper 
If the unit is forcibly opened or it is removed from the wall, a tamper 
event is triggered. A tamper output opens sending a signal to the 
connected alarm system (purple wire); the event closes when the 
tamper is closed (case is re-closed or re-attached to the wall). 
The tamper event can also activate the auxiliary output if the 
controller is in Auxiliary Mode 3 (refer to Table 5). 
6.7
 
Lockout Feature (Keypad/Card Tamper) 
If the controller is presented with wrong codes (PIN or Card) 
consecutively several times, the unit goes into Lockout mode. 
When a lockout
 
occurs, the controller’s reader and keypad are de-
activated so no codes can be entered until the set lockout period 
expires. 
During Lockout, Mode LED is
 
off, the Door LED flashes red, and the 
controller beeps every two seconds
.
 
6.8
 
21B
REX Function 
The REX button is connected to a Rosslare secured series intelligent 
power supply. The REX button must be located inside the premises to 
be secured and is used to open the door without the use of a PIN 
code. It is usually located in a convenient location, such as inside the 
door or at a receptionist's desk. The function of the REX button 
depends on whether the Lock Strike Relay is programmed for Fail Safe 
Operation or Fail Secure Operation.