Rosslare Enterprises Ltd AYC-E60 Manuel D’Utilisation

Page de 73
Controller Functionality 
54 
AYC-E/Q60 Family Instruction Manual 
6.10.10.6
 Auxiliary Mode 5 
Auxiliary input function: Door Monitor 
Auxiliary output activated by: Shunt (explanation below) 
For example, in Auxiliary Mode 5, the controller is capable of shunting 
an alarm system. In this mode, the auxiliary input is to be wired to the 
magnetic contact switch on the door. The auxiliary relay is wired to 
the alarm system. Without a valid code entered, the auxiliary relay 
matches the condition of the magnetic contact switch; if the door 
opens, the auxiliary relay opens; if the door closes, the auxiliary relay 
closes. When a valid code is entered, a countdown for maximum 
shunt time, as defined by the auxiliary setting, begins; if the door is 
not closed before the maximum shunt time, the alarm is triggered. 
6.10.10.7
 Auxiliary Mode 6 
Auxiliary input function: Door Monitor 
Auxiliary output activated by: Forced entry 
For example, in Auxiliary Mode 6, the controller can trigger the 
auxiliary relay if the door has been forced. If the siren settings are 
enabled, the siren is activated. 
In this mode, the auxiliary input functions as a door monitor switch 
and is wired to the magnetic contact switch on the door. The auxiliary 
relay is to be wired to the alarm system. If the door is forced open, 
the controller waits for the period of the forced door delay time to 
elapse and then it activates the auxiliary relay. The auxiliary setting 
sets the forced door delay period. 
6.10.10.8
 Auxiliary Mode 7 
Auxiliary input function: Door Monitor 
Auxiliary output activated by: Door Ajar (door held open) 
For example, in Auxiliary Mode 7, the controller can trigger the 
auxiliary relay, if it detects that the door has been held open (ajar) too 
long. In this mode, the auxiliary input functions as a door monitor 
switch and is wired to the magnetic contact switch on the door. The 
auxiliary relay is to be wired to the alarm system. If the door is 
opened, the controller waits for the Door Ajar Delay time to elapse