Badger Meter Inc 2010W Manuel D’Utilisation

Page de 20
Installation Data
Using the charts below, connect the ORION Universal 1 endpoint to an approved encoder according to the following guide 
lines. Verify the endpoint serial number prior to completing the wiring set up.
ORION Endpoints - Serial Number > 80,000,000
Universal 1 
Endpoint 
Wire
Sensus 
ECR II, 
ICE
Neptune 
ProRead
Elster  
AMCo 
ScanCoder
AMCO 
Invision
ARB-
V**
Metron 
Hawkeye
Red
R
B
G
G
B
B
Black
B
G
B
B
G
B
Green
G
R
R
R
R
G
ORION Endpoints - Serial Number < 79,999,999
Universal 1 
Endpoint 
Wire
Sensus 
ECR II, 
ICE
Neptune 
ProRead
Elster  
AMCo 
ScanCoder
ARB-V**
Metron 
Hawkeye
Red
R
B
G
R
B
Black
B
G
B
B
B
Green
G
R
R
G
G
R = Red            B = Black           G = Green
*Due to the customized, factory wire configurations of the Hersey translator, please contact Badger Meter for proper wiring 
guidelines. 
**A separate ORION endpoint is available for connectivity to the Neptune ARB-V encoder.
Connect the encoder cable wires to the ORION Universal endpoint wires using the insulation gel connectors provided in the 
installation kit. Refer to the chart to determine which wires need to be connected to complete an installation.  The ORION 
system was designed as a three-wire AMR system. 
The ORION system offers connectivity to any of the mechanical/absolute encoder registers listed above, with a manufacture 
date between 2000 to the present, as long as the encoder is programmed into the three-wire output mode for AMR and has 
three wires connected to it. Encoder registers that are currently in two-wire mode of operation will require programming 
by the Utility, including registers that support auto two or three wire detection systems that do not automatically switch to 
three-wire mode of operation once a compatible endpoint is connected for ORION connectivity.
Do not strip any insulation from the ends of the wires before you push them into the connector.
Push the wires that are to be connected together as far as possible into the connector.
Figure 18: Wires In Connector
Using the required Gel Splice Crimping Tool, Badger Meter number 59983-001, place the connector with the wires into the 
jaws of the crimping tool.
 (12-10)
Page 17