Toshiba TEC Corporation HTK10 Manuel D’Utilisation

Page de 66
User manual                                                   HANDY TERMINAL
 
50
 
 
 
 
 
 
 
 
9.20.
 
  Scanner Settings Applet
 
Tab 
Section 
Option 
Description 
Basic 
Scanning
 
Trigger timeout (sec) 
Specifies  the  trigger  time  out  in 
seconds. If a barcode is not 
decoded within the specified 
timeout, the default Notifier 
indicates that decoding is failed 
Enable Auto Scan 
Enable  Auto  Scan  with  specified 
interval. 
Auto Scan interval (sec) 
Set Auto Scan interval time. 
Continuous Scan 
Enable Continuous Scan without 
any interval. 
Enable Center   
Window(IT5300SR 
device   
only) 
Enable Center window. Bar 
codes  are  decoded  only  if  they 
are within the specified windows 
Decode  Mode(IT5300SR 
device only) 
Standard:   
Quick Omni 
(By default)
:   
Delay Before   
Decoding(IT5300SR 
device only) 
Start to decoding after specified 
milliseconds 
Values:  0(default),  100,  200, 
300,  400,  500,  600, 
700, 800, 900, 1000 
Wedge mode 
User Message 
Select Result Type 
User Message 
Keyboard Event 
Clipboard(default) 
Terminator 
Select  the  desired  barcode  end 
method from the pull down list. 
 
Values: None, CRLF, Space, 
Tab 
Power Save Options 
(N4313 device only)
 
Power Save Mode 
Select Power Save Mode 
OFF 
SLEEP 
HIBERNATE(default) 
Power Save TimeOut 
(sec) 
1~65535