GatesAir Inc. UAXFLID Manuel D’Utilisation
2-12
888-2721-001
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
Maxiva UAX Transmitter Indoor System
User Manual
2.10 Initial Turn-On
Read and understand the entire initial turn-on procedure before starting. Descriptions
and operational instructions for TCU and LPU GUI screens is given in Section 3
"Operation" in the UAX Transmitter manual.
and operational instructions for TCU and LPU GUI screens is given in Section 3
"Operation" in the UAX Transmitter manual.
STEP 1
Make sure the output RF line is connected properly. If connecting to a
load, verify the load connections are proper and that load conditions are
met.
met.
!
CAUTION:
THE TRANSMITTER RF LINE MUST BE CONNECTED TO A KNOWN GOOD LOAD
OR ANTENNA. IF THE CONDITION OF THE LOAD OR ANTENNA ARE IN DOUBT
THEY SHOULD BE MEASURED WITH A NETWORK ANALYZER PRIOR TO TURNING
ON THE TRANSMITTER.
OR ANTENNA. IF THE CONDITION OF THE LOAD OR ANTENNA ARE IN DOUBT
THEY SHOULD BE MEASURED WITH A NETWORK ANALYZER PRIOR TO TURNING
ON THE TRANSMITTER.
STEP 2
Verify all ground connections are secure and the AC power feed
connections from the facility AC power source are tight and of proper
capacity (correct gauge wire, breaker size etc.).
capacity (correct gauge wire, breaker size etc.).
STEP 3
Verify the AC access cover is properly installed on the top of the
transmitter.
STEP 4
Check the transmitter cabinet for any loose hardware. Visually inspect
that all cable/wire/cord connections are secure.
STEP 5
Check that all AC mains breakers for the transmitter system are OFF. All
circuit breakers on the AC distribution panel at the top front of the
transmitter cabinet should also be OFF.
transmitter cabinet should also be OFF.
STEP 6
Apply AC primary power to the enclosure system. Be ready to quickly
disconnect the power if necessary.
STEP 7
If the system has a UPS unit, it must be turned ON to power the rest of
the system. Check the UPS manufacturer’s manual for procedure.
STEP 8
To turn the Transmitter on, refer to the procedure in the Transmitter
manual. It begins by turning each of the transmitter breakers ON. These
are the breakers in the breaker panel at the top of the transmitter. Only
the transmitter is connected to these breakers.
are the breakers in the breaker panel at the top of the transmitter. Only
the transmitter is connected to these breakers.
STEP 9
After the Transmitter is turned ON, verify power out is correct on the
TCU Home Screen. Refer to the transmitter manual for detailed
operation of all transmitter functions and operation.
operation of all transmitter functions and operation.