Hokuyo Automatic Co Ltd MBX301CANA Manuel D’Utilisation
HOKUYO AUTOMATIC CO.,LTD.
(2) Phenomenon : Control output signal executes although there is no detectable objects in detection area.
13. Reference
Tokyo Office
Shinbashi Ekimae No. 2 Bldg., 2-21-1 Shinbashi, Minato-Ku, Tokyo 105-0004, Japan
Tel : 03-3572-2846
Fax : 03-3572-2734
Nagoya Office
Ryoshin Bldg., 4-8-12 Meieki, Nakamura-Ku, Nagoya 450-0002, Japan
Tel : 052-582-4641
Fax : 052-551-6906
Osaka Office
1-10-9 Niitaka, Yodogawa-Ku, Osaka 532-0033, Japan
Tel : 06-6394-2102
Fax : 06-6394-2339
Kyushu Office
KMM Bldg., 2-11-15 Asano, Kokurakita-Ku, Kitakyushu 802-0001, Japan
Tel : 093-551-2189
Tel : 052-582-4641
Fax : 052-551-6906
Osaka Office
1-10-9 Niitaka, Yodogawa-Ku, Osaka 532-0033, Japan
Tel : 06-6394-2102
Fax : 06-6394-2339
Kyushu Office
KMM Bldg., 2-11-15 Asano, Kokurakita-Ku, Kitakyushu 802-0001, Japan
Tel : 093-551-2189
Fax : 093-551-2189
Title
Waveguide Type Micro Master
MBX-301CA-NA Instruction Manual
Drawing
No.
C-91-315 24/24
Is power lamp(POWER) lighting up?
Is supply voltage correct?
Is wiring correct?
Make a wiring
Is operation lamp(OPERATION)
lighting up?
Are there any reflective
objects in detection area?
Remove reflective objects.
Is waveguide off?
Is joint loosening?
Make a piping again.
Tighten more.
Replace control box to new one.
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES