AMS-9060 CONTROLLER 
8200-1014-01, REV. 1A 
INSTALLATION GUIDE 
3 of 13
 
Installation Requirements 
Verifying Equipment and Unpacking 
  Verify that all equipment has arrived. Ensure the 
system configuration is correct for the site. 
  Unpack major components in a back room. At 
the install site, lay out parts in the order used. 
Do not clutter the aisle or cause a trip hazard. 
Installer/Contractor 
  Have electrical work comply with the latest 
national electrical code, national fire code, and 
all applicable local codes and ordinances. 
  Coordinate work with other trades to avoid 
interference. 
  Verify existing site conditions and coordinate 
with the owner’s representative and appropriate 
utilities as required. 
  Obtain copies of all related plans, specifications, 
shop drawings and addenda to schedule and 
coordinate related work. 
  Thoroughly review the project to ensure that all 
work meets or exceeds the above requirements. 
Bring alleged discrepancies to the attention of 
Sensormatic Electronics. 
Mounting Requirements 
  The controller has a built-in flange used to 
attach the controller to a wall or ceiling using 
suitable hardware. Structure and hardware must 
support 12.08kg (26.06 lbs) or four times the 
weight of the controller assembly. 
  Do not mount controller with its fan facing up. 
AC Requirements 
WARNING
—RISK OF ELECTRIC 
SHOCK!
 During installation, if the 
antenna must be left unattended, turn off 
power or cover high voltage components 
to prevent unauthorized access to 
hazardous voltages. 
WARNING
—RISK OF ELECTRIC 
SHOCK! 
The ac power cord could be 
carrying 120Vac or 240Vac. 
WARNING!
 Do not install this device 
where highly combustible or explosive 
products are stored or used. 
WARNING! 
The ac source must be a 2-
wire type with ground. It also must be a 
24-hour, unswitched outlet with less than 
0.5Vac between neutral and ground. 
WARNING! 
This device is not suitable 
for an IT power distribution system 
where impedance exists between neutral 
and protective earth contacts. 
CAUTION: When using a power cord, 
install a socket-outlet near the controller 
in an easily accessible location. The 
appliance coupler or plug on the power 
supply cord are the specified disconnect 
devices. 
CAUTION: DO NOT share the ac source 
with neon signs, motors, computers, 
cash registers, terminals, or data 
communications equipment. 
CAUTION: DO NOT use orange-colored 
outlets dedicated for computer 
equipment. 
CAUTION: Select the appropriate power 
cord based on the country of use. 
Mounting the Controller 
The controller can be mounted as follows: 
  On a shelf. 
  On a wall.  
  To a ceiling. Plywood with a surface larger than 
the controller is secured to the ceiling studs that 
hold the drywall. The controller then attaches 
with suitable hardware to the plywood. 
Equipment Required 
Basic setup requires the following equipment: 
  AMS-9060 controller 
  Pedestal antennas 
  Hard tag (non-
deactivatable Ultra•Max tag) 
 
Ultra•Max low energy labels. 
Advanced setup requires the following additional 
equipment: 
  Laptop with Windows
® 
7, Windows
® 
95, 
Windows
® 
98, Windows
® 
NT, or Windows
® 
2000, 
operating software 
  RS-2
32 Ultra•Max programming cable 
  ADS 4 service configurator software.